Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Biomech Eng ; 146(5)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38376458

RESUMO

The global learning initiative at Northeastern University is focused on fostering intercultural communication skills. The Dialogue of Civilization (DOC) program serves as a mechanism to achieve such a goal by offering faculty-led international experiences. In this paper, we have presented a detailed account of a DOC program that took place in Norway. The primary objective of the program was to teach mechanical engineering and bio-engineering students computational skills while stimulating critical thinking about the cultural and social aspects of technology and engineering in Norway. The program focused on two courses: a technical course and a special topics course. The technical course introduced students to finite element analysis, with practical applications and site visits in Norway to enhance experiential learning. In the special topics course, the interplay between modern technologies, like green energy, state policies, and the rights and traditions of the indigenous Sámi people was explored. The course highlighted both the progressive social policies in Norway and the historical discrimination against the Sámi. Student feedback was positive and experiential learning components such as guest lectures and site visits were particularly appreciated. Additional surveys showed that students' self-confidence was higher following the DOC program. In addition, female-identifying students had higher confidence in their future success after completion of this program as compared to their male-identifying counterparts. Our paper is expected to serve as a resource for educators seeking to integrate technical education with intercultural experiences and discussions on social and cultural impacts in engineering.


Assuntos
População do Leste Europeu , Aprendizagem Baseada em Problemas , Estudantes , Feminino , Humanos , Masculino , Bioengenharia , Aprendizagem , Noruega
2.
PLoS One ; 17(5): e0267131, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35560311

RESUMO

Elastin is present in the extracellular matrix (ECM) of connective tissues, and its mechanical properties are well documented. In Marfan syndrome, however, the inability to properly code for the protein fibrillin-1 prematurely leads to the degradation and loss of elastin fiber integrity in the ECM. In this study, the role of elastin in the ECM of the anterior leaflet of the tricuspid valve was investigated by examining the biomechanical behavior of porcine leaflets before and after the application of the enzyme elastase. Five loading protocols were applied to the leaflet specimens in two groups (elastase-treated and control samples). The mechanical response following elastase application yielded a significantly stiffer material in both the radial and circumferential directions. At a physiological level of stress (85 kPa), the elastase group had an average strain of 26.21% and 6.32% in the radial and circumferential directions, respectively, at baseline prior to elastase application. Following elastase treatment, the average strain was 5.28% and 0.97% in the radial and circumferential directions, respectively. No statistically significant change was found in the control group following sham treatment with phosphate-buffered saline (PBS). Two-photon microscopy images confirmed that after the removal of elastin, the collagen fibers displayed a loss of undulation. With a significant reduction in radial compliance, the ability to withstand physiological loads may be compromised. As such, an extracellular matrix that is structurally deficient in elastin may hinder normal tricuspid valve function.


Assuntos
Elastina , Valva Tricúspide , Animais , Fenômenos Biomecânicos , Elastina/metabolismo , Matriz Extracelular/metabolismo , Elastase Pancreática/metabolismo , Estresse Mecânico , Suínos
3.
Exp Eye Res ; 202: 108373, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33253707

RESUMO

Nuclear shape alteration in ocular tissues, which can be used as a metric for overall cell deformation, may also lead to changes in gene expression and protein synthesis that could affect the biomechanics of the tissue extracellular matrix. The biomechanics of iris tissue is of particular interest in the study of primary angle-closure glaucoma. As the first step towards understanding the mutual role of the biomechanics and deformation of the iris on the activity of its constituent stromal cells, we conducted an ex-vivo study in freshly excised porcine eyes. Iris deformation was achieved by activating the constituent smooth muscles of the iris. Pupillary responses were initiated by inducing miosis and mydriasis, and the irides were placed in a fixative, bisected, and sliced into thin sections in a nasal and temporal horizontal orientation. The tissue sections were stained with DAPI for nucleus, and z-stacks were acquired using confocal microscopy. Images were analyzed to determine the nuclear aspect ratio (NAR) using both three-dimensional (3D) reconstructions of the nuclear surfaces as well as projections of the same 3D reconstruction into flat two-dimensional (2D) shapes. We observed that regardless of the calculation method (i.e., one that employed 3D surface reconstructions versus one that employed 2D projected images) the NAR increased in both the miosis group and the mydriasis group. Three-dimensional quantifications showed that NAR increased from 2.52 ± 0.96 in control group to 2.80 ± 0.81 and 2.74 ± 0.94 in the mydriasis and miosis groups, respectively. Notwithstanding the relative convenience in calculating the NAR using the 2D projected images, the 3D reconstructions were found to generate more physiologically realistic values and, thus, can be used in the development of future computational models to study primary angle-closure glaucoma. Since the iris undergoes large deformations in response to ambient light, this study suggests that the iris stromal cells are subjected to a biomechanically active micro-environment during their in-vivo physiological function.


Assuntos
Iris/patologia , Miose/patologia , Mióticos/farmacologia , Midríase/patologia , Midriáticos/farmacologia , Células Estromais/patologia , Animais , Modelos Animais de Doenças , Combinação de Medicamentos , Microscopia Confocal , Miose/induzido quimicamente , Midríase/induzido quimicamente , Fenilefrina/farmacologia , Pilocarpina/farmacologia , Células Estromais/efeitos dos fármacos , Suínos , Tomografia de Coerência Óptica , Tropicamida/farmacologia
4.
J Biomech ; 98: 109462, 2020 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-31718820

RESUMO

Mechanical testing of soft tissues would ideally rely on using fresh specimens. In the event that fresh tissues are not readily available, alternative measures, such as storing fresh specimens at -80 °C, could be considered. Previous studies have shown that changes in the mechanical properties of the tissues due to freezing could be tissue-dependent. Prior to our study, however, such information was not available for the tricuspid valve leaflets. As such, for the first time, we examined whether fresh porcine specimens tested in a biaxial tensile machine would offer comparable results after being frozen at -80 °C. The stress-strain response of the tricuspid valve leaflets displayed no major deviation of the post-frozen leaflets as compared to fresh leaflets. We further compared the radial and circumferential strains as an indicator of deformation at similar stress states in fresh and thawed tissues, and we did not find any significant differences. Ice formation within the extra cellular matrix may modify the collagen fiber configuration, resulting in a slight change in the mechanical response. Nevertheless, our results indicated such a small deviation was negligible, thus enabling the possibility of using frozen porcine tricuspid valve specimens for future research.


Assuntos
Criopreservação , Congelamento , Fenômenos Mecânicos , Valva Tricúspide , Animais , Fenômenos Biomecânicos , Estresse Mecânico , Suínos , Fatores de Tempo
5.
Bioengineering (Basel) ; 6(3)2019 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-31443151

RESUMO

Since many soft tissues function in an isotonic in-vivo environment, it is expected that physiological osmolarity will be maintained when conducting experiments on these tissues ex-vivo. In this study, we aimed to examine how not adhering to such a practice may alter the mechanical response of the tricuspid valve (TV) anterior leaflet. Tissue specimens were immersed in deionized (DI) water prior to quantification of the stress-strain responses using an in-plane biaxial mechanical testing device. Following a two-hour immersion in DI water, the tissue thickness increased an average of 107.3% in the DI water group compared to only 6.8% in the control group, in which the tissue samples were submerged in an isotonic phosphate buffered saline solution for the same period of time. Tissue strains evaluated at 85 kPa revealed a significant reduction in the radial direction, from 34.8% to 20%, following immersion in DI water. However, no significant change was observed in the control group. Our study demonstrated the impact of a hypo-osmotic environment on the mechanical response of TV anterior leaflet. The imbalance in ions leads to water absorption in the valvular tissue that can alter its mechanical response. As such, in ex-vivo experiments for which the native mechanical response of the valves is important, using an isotonic buffer solution is essential.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...